LEAP Bridge Steel Help

Deck Placement Sequence Dialog

Opens when Deck Placement Sequence is selected in the Analysis group.
SettingDescription
Add Stage Press this button to add a stage to the deck placement sequence.
Delete Stage Press this button to delete the currently highlighted stage in the grid.
Name Enter the stage name. The first stage is always initial and the last stage is always final.
Component Steel This non-editable column is always set to steel because there is always a steel component. This section is for reference only.
Component Concrete For each stage other than Initial and Final, the drop-down list in this column allows the selection of the slab segments that are being poured in the stage. The slab segments that can be selected will be those defined in the Deck Slab command. The system will allow a given slab segment to be selected in one stage only.
Deck Overhang

Enter construction load value to compute the flange moment(with the appropriate factors applied based on the user selected Strength load combination), flange moment which will be passed to the code checker. For more details, check below Deck Overhang Loads topic.

Const

Enter construction load value to compute the flange moment(with the appropriate factors applied based on the user selected Strength load combination), flange moment which will be passed tot the code checker.

Fin. Machine

Enter construction load value to compute the flange moment(with the appropriate factors applied based on the user selected Strength load combination), flange moment which will be passed to the code checker.

Save DGN Press this button to export all member group geometry to a MicroStation .dgn file. Save the .dgn file to the desired location and once the export is complete you can browse to the file location and open/view it in MicroStation
OK Press this button to accept all changes and exit the command.